<img alt="" src="https://secure.companyperceptive-365.com/785321.png" style="display:none;">
Our weld lead and power lead cables are subject to extreme conditions. They lie in oils, solvents, soaps, and are subject to being run over by forklifts and other machinery. Previous to TPC, we changed out cable two to three times per year on each of our eight welding machines. Some of our machines have been equipped with TPC cable for three full years!
Dennis D. Bullock
Boilermaker Leadman, Northtown Diesel Shop, Burlington Northern Railroad
Reduce downtime, labor, and overall cost of ownership - Request a cost value analysis

Case Study: Paper Mill Conquers Heat and Moisture Issues with Lighting Fixtures Using Chem-Gard® 200

Case Study-web-Image-Papermill

PROBLEM:

One of the world’s leading producers of fiber-based packaging, pulp, and paper was experiencing routine failure of cable on a lighting fixture at its mill in Oklahoma due to the hot wet environment. For each instance of failure, the cost to replace cable was $996 in parts and labor plus 6 hours of production time.

SOLUTION:

The TPC representative suggested Chem-Gard® 200 Unshielded Single-Conductor Cable, known for its excellent resistance to chemicals, abrasion, and high heat. Finely stranded, nickel-plated copper conductors improve flexibility and protect against corrosion and oxidation in chemical and high-temperature environments. Fluoropolymer insulation is extremely resistant to chemicals and also mechanically durable. High-temperature fluoropolymer fillers will not wick up contaminants and allow conductors to move freely. A fluoropolymer jacket designed for continuous temperatures up to 200ºC (392ºF) is also resistant to oils, acids, solvents, and chemicals, and provides excellent defense against cutting and abrasion. Roughly 40% smaller in diameter than SOOW cable, the solution is also useful in areas with restricted space and/or in conduit.

RESULT:

In service for 21 months, the total expense for TPC’s solution was just $1,620 for parts and labor compared to the nearly $3,000 the customer would’ve spent using its former cable. TPC saved the customer $1,368 and, perhaps more importantly, increased production time by 12 hours.

 

Download the printable PDF.

Our weld lead and power lead cables are subject to extreme conditions. They lie in oils, solvents, soaps, and are subject to being run over by forklifts and other machinery. Previous to TPC, we changed out cable two to three times per year on each of our eight welding machines. Some of our machines have been equipped with TPC cable for three full years!
Dennis D. Bullock
Boilermaker Leadman, Northtown Diesel Shop, Burlington Northern Railroad

Your Solution Starts Here

Reach out today, and an experienced technical expert will contact you to assess your needs and provide an initial quote.
Request A Quote